ALL-IN-ONE NETWORK ANALYZER

HIGHLY AVAILABLE DATA – SECURE COMMUNICATION

Transparency across all data levels is a key success factor for modern companies. The recording and consolidation of data from all areas of the company is necessary, for example, to establish safety measures to protect plant and machinery and to save costs.

This goal is associated with many challenges, as different standards, interfaces and communication options have to be coordinated. The networking of previously isolated areas, from the machine level to ERP systems and building management systems, is very complex. OPC UA is a standardization of data transmission that simplifies this consolidation.

The Janitza UMG 801 energy measurement device offers various communication interfaces and enables direct data transmission via OPC UA to higher-level systems.

The modularly expandable UMG 801 is ideal for the complete recording of an energy management system (in accordance with ISO 50001). You receive transparency about the energy consumption and energy costs of all exhibition levels.

A BRIEF OVERVIEW OF CENTRAL FUNCTIONS AND EXTENSIONS CAN BE FOUND IN OUR PRODUCT VIDEO

UMG 801 – ALL-IN-ONE NETWORK ANALYZER

ALL IN ONE DEVICE

  • 8 current measurement channels with 1/5 A inputs on the base unit
  • 4 multifunction channels on the basic device, optionally configurable as RCM, temperature measurement channels or additional current measurement channels via mA signals
  • Generous onboard measurement data memory with 4 GB for storing measurement data
  • Two groups with four digital IOs each (tariff switching and pulse input, logical states)
  • Analog output (direct current 0/4-20mA)

MEASURE WITH HIGH PRECISION

  • High sampling frequency (51.2 kHz voltage)
  • 1024 samples for voltage measurement
  • High measuring accuracy on all channels (V: 0.2 % / A: 0.2 % / kWh: class 0.2)
  • Highest safety: 1000V CAT III
  • Extensive power quality parameters
    • Tension up to the 127th harmonic and interharmonic
    • THD-U and THD-I
    • Asymmetry
    • Event and transient detection

VISUALIZE, DOCUMENT AND ANALYZE

  • Integrated colour graphic display for visualization and intuitive configuration on site as well as optional colour graphic display for front panel operation
  • Extensive options for visualization, analysis and documentation of energy measurement data (GridVis® software)
  • Integrated automatic report generation (GridVis® software)

MANAGE AND USE DATA

  • Simple integration of the measurement data from the basic device and measurement modules into higher-level systems (e.g. building management systems, SCADA systems)
  • Cybersecurity: Integrated security mechanisms to protect against unauthorized access and misuse
  • Configuration of the entire measurement system via OPC UA
  • Future-proof software architecture, as the OPC UA standard grows with new applications

FUTURE-PROOF INVESTMENT

  • Modular extension of the measuring points with measuring modules.
  • Open and future-proof communication through various interfaces and OPC UA server.

MINIMAL INTEGRATION EFFORT

  • Easy integration into a higher-level system thanks to open communication architecture via OPC UA standard (e.g. BMS, SCADA and ERP applications).
  • Multiple and simultaneously usable interfaces.
  • Gateway functionality for integrating additional devices, e.g. Janitza UMGs from downstream measurement levels.

MAXIMUM DATA SECURITY

  • Secure communication through OPC UA security structures.
  • Data retention (redundancy) provided by onboard memory of the basic device.
  • Modbus TCP/IP whitelisting to prevent unwanted access

VOLTAGE QUALITY

  • Recording, analyzing and documenting disturbance variables, e.g. harmonics
  • Event and transient detection with storage in PQDiff and Comtrade
  • Extensive visualization in the event browser
  • Event and transient detection with storage in PQDIF and Comtrade format

DEVICE HOMEPAGE

  • Integrated web server on the base unit for needs-based configuration without the use of additional software

EXTREME VALUE DETECTION

  • Easy-to-use extreme value acquisition for the most important measured variables such as conductor currents and voltages

COMMUNICATION

  • 2 Ethernet interfaces for simultaneous (switched mode) or separate (dedicated mode) use
  • Complex measuring devices and module topologies can be realized with separate use

FLEXIBLE CONNECTION

DATA ACCESS MADE EASY

The networking options of the UMG 801 maximize its benefits and minimize the integration effort in higher-level systems. The device has two simultaneously usable Ethernet interfaces for direct cabling and data transmission, as well as an RS 485 interface for reading out the acquired data or for setting up a measurement topology.

With the OPC UA standard, you also benefit from a software architecture with integrated security mechanisms. This significantly simplifies the merging of data from all areas of the company, another milestone in the implementation of Industry 4.0.