Main features of the UMG 604-PRO
HARMONICS
Harmonics are caused by equipment with non-linear characteristics, such as transformers operated in saturation, energy-saving lamps, frequency converters and power electronics. They burden the grid with additional currents and can affect or even destroy equipment. These grid perturbations can be detected and documented using power quality analyzers.
MEASURING DEVICES-HOMEPAGE
The web server on the measuring device provides a wide range of data in a clearly structured form. The user does not need to install any software on his PC, a standard web browser is sufficient. The user enters the IP address of the measuring device in the URL window of the browser and the homepage of the measuring device appears on the screen. In addition to the modern homepage, APPs are also available for an extended range of functions.
JASIC®
With the Jasic® graphical programming language, the user can add their own functions to a UMG measurement device. Up to seven freely definable user programs can run in parallel, e.g. monitoring of processes or messages when defined limit values are reached. In addition to graphical programming, the user is free to program the code directly in JASIC.
EVENTS
Events are short-term voltage increases or dips, overcurrents or short-term interruptions (e.g. due to bird strikes or short circuits). UMG measuring devices can reliably record and process events from 20 ms and transients from 50 μs duration. This allows the causes of power quality fluctuations to be identified and analyzed.
ETHERNET-MODBUS-GATEWAY
Modbus RTU devices that are connected to the master device as slaves can be very easily integrated into an Ethernet architecture via the Ethernet Modbus gateway. For devices with an identical file format and matching function codes, this is possible directly via the Modbus RTU interface.
MEMORY
Many UMG measurement devices have their own memory with typical recording ranges of up to 2 years. Recording is freely configurable. A 128 MByte memory can store around 5,000,000 memory values, a 256 MByte memory can store around 10,000,000 memory values.
Areas of application
- Master device for energy management systems (e.g. ISO 50001)
- Measurement, monitoring and control of electrical parameters in power distribution systems
- Consumption data acquisition
- Monitoring the power quality (harmonics, short-term interruptions, transients, starting currents, …)
- Transducer for building management system or PLC
- Control tasks, e.g. depending on measured or limit values reached
- Peak load optimization
- Ethernet gateway for subordinate measuring points
- Remote monitoring
VOLTAGE QUALITY
- Harmonic analysis up to the 40th harmonic
- Unbalance Distortion factor THD-U / THD-I
- Measurement of positive, negative and zero sequence
- Short interruptions (from 20 ms)
- Recording and storage of transients (> 50 μs)
- Start-up processes
- Fault recorder function
- Rotary field display
DIN RAIL MOUNTING (6TH): SIMPLE AND COST-OPTIMIZED INSTALLATION
- Mounting on a 35 mm top-hat rail
- Clear cost advantage in control cabinet construction due to lower installation and connection costs
- Easy integration in LVAC, in mechanical engineering, in installation distributors in building technology, in information technology and in data centers
MODERN COMMUNICATION ARCHITECTURE VIA ETHERNET
- Fast, cost-optimized and reliable communication through connection to an existing Ethernet architecture
- Integration in PLC systems and BMS
- High flexibility through the use of open standards
- Simultaneous query of the interfaces possible
ETHERNET-MODBUS-GATEWAY AND HIGHSPEED-MODBUS
- Simple integration of Modbus RTU devices into an Ethernet architecture using the Modbus gateway function
- Integration of devices with identical file format and matching function codes possible via Modbus RTU interface
- Fast and reliable data transmission via RS485 interface
- Speed up to 921.6 kB/s
GRAPHIC PROGRAMMING
- Extensive programming options on the device, 7 programs simultaneously (PLC functionality)
- Jasic® source code programming
- Functional enhancements far beyond pure measurement
- Ready-made APPs from the Janitza library
LARGE MEASUREMENT DATA MEMORY
- 128 MByte
- 5,000,000 Memory values
- Recording range up to 2 years
- Recording freely configurable
Device website
THE EVALUATION AVAILABLE AT ANY TIME
Each measuring device has an integrated web server with its own homepage. The measuring device can be operated via the device’s own homepage as well as via the device display.
In addition, current and historical measurement data, including power quality parameters, can be called up on a large scale. The advantage of the device homepage is the constant availability of measurement data – without prior software installation.
The user immediately receives an overview of all energy data. The device homepage can be displayed on any end device and is adapted according to the device functions (responsive design).
The uniform design of the GridVis® visualization software and the device homepage makes it easy to use.
YOUR BENEFITS
- Access to the powerful device homepage via web browser
- Constant availability of measurement data
- No software installation necessary
- Online data, historical data and much more can be called up directly via the device homepage
- Functional expansion through APPs possible
- Remote control of the device display via the homepage
- Integrated PQ watchdogs
- Hyperlinks provide more detailed information
- Integrated measured value monitor
- Overview of events and transients in the network
- Convenient selection of the calculation mode for displaying measurement data in accordance with the IEC 61000-2-4 or EN 50160 standard (applies to the UMG 605-PRO and UMG 512-PRO)